wall results command
Syntax
- wall results keyword ...
Primary keywords:
Modify the usage of the wall results logic. This logic allows for a reduced version of the model state (i.e., wall geometries plus wall attributes) at different instances of time to be output as binary files. The wall result can be used to re-create the model state, acting as a utility for efficient post processing (e.g., movie generation, residence time calculations, etc.). A wall result file DOES NOT replace a PFC model state file and models re-created with this logic should not be cycled. See the
model resultscommand to specify when results files are created and how to import these files subsequently.- active b
Set the status of wall result creation.
- add-attribute s
Add the wall attribute s (as defined in the
wall attributecommand) to be recorded in the wall result. When the result is re-created, this attribute will be filled. All wall attributes can be listed with thewall list attributecommand. Wall group and extra variables can also be added using the group and extra keywords.
- remove-attribute s
Remove the wall attribute s (as defined in the
wall attributecommand) to be recorded in the wall result. Wall group and extra variables can be removed using the group and extra keywords.
Usage Example
wall result active on
from “Hopper.dat” in Hopper Discharge
wall result add-attribute velocity
from “fragment.dat” in Fragmentation Analysis during a Uniaxial Compression with Crack Tracking Using Fractures
| Was this helpful? ... | FLAC3D © 2019, Itasca | Updated: Feb 25, 2024 |