Logo  

structure link slide-tolerance command

Syntax

structure link tolerance-slide f <range>

Set the tolerance used when updating node-to-zone links in response to large-strain motion. A node is considered to be in a zone if it is within a distance \(\delta\) of the zone boundary, where \(\delta\) equals f times zone size (taken as the maximum \(x\)-, \(y\)-, or \(z\)-dimension of the zone bounding box). By default, f equals 1 × 10-5.

⇄
  • Itasca Software 9.4 documentation »
  • Itasca Software Guide »
  • Structural Elements »
  • Structural Element Links »
  • Commands »


⇐ structure link tolerance-node command | FISH Functions ⇒
Was this helpful? ... Itasca Software © 2024, Itasca Updated: Jun 07, 2025