Logo  

structure link dynamic-damping command

Syntax

structure link dynamic-damping keyword ... <range>

Primary keywords:

none    maxwell

Set dynamic damping type to the link.

none

No Maxwell damping.

maxwell fd1 f1 fd2 f2 fd3 f3 <off-when-yield b >

Maxwell damping (see Maxwell Damping) for all conformable structural links in the range. f1 is the center frequency of the first Maxwell component and fd1 is the maximum damping ratio of the first Maxwell component; f2 is the center frequency of the second Maxwell component and fd2 is the maximum damping ratio of the second Maxwell component; f3 is the center frequency of the third Maxwell component and fd3 is the maximum damping ratio of the third Maxwell component. This command must be issued when the dynamic option is configured and turned on. If off-when-yield = on/yes/true (default), the Maxwell damping will be inactivated when the constitutive model is yielding; If off-when-yield = off/no/false, the Maxwell damping will still be active when the link constitutive model is yielding.

⇄
  • Itasca Software 9.4 documentation »
  • Itasca Software Guide »
  • Structural Elements »
  • Structural Element Links »
  • Commands »


⇐ structure link delete command | structure link group command ⇒
Was this helpful? ... Itasca Software © 2024, Itasca Updated: Jun 07, 2025

9.4.31